AI in the NHS

Which systems are running, what they have been measured to do, and where the published evidence stops.

There is no national figure for AI use in the NHS. No dataset records which trusts run which systems, and the surveys that cover every provider ask about digital maturity rather than AI. Radiology is the exception, and it is where this page starts.

Two distinctions run through what follows. The first is between rules-based decision support and machine learning, both of which get called AI and which fail in different ways. The second is between an outcome measured after a system went live and a figure that was modelled or simply asserted. Of 9 published outcomes across the 7 deployments listed below, 5 were measured after deployment.

AI use in imaging and oncology

Data as of September 2025

Radiology is the only speciality where anyone counts AI use across the whole United Kingdom. The Royal College of Radiologists asks every radiology department and cancer centre whether it uses AI tools for at least one clinical purpose, and publishes the answers by nation and region. In the September 2025 censuses, 75% of radiology departments and 81% of cancer centres said they did.

Share of trusts and health boards using AI tools for at least one clinical purpose. The denominator is those answering the AI question, which is at or below the number in the census.

The censuses give a single reading rather than a series. Neither 2025 workbook carries a comparable figure for 2024: the oncology sheet has a 2024 comparison column and it reads not applicable for this row. A figure of 69% for 2024 circulates in secondary coverage and appears in neither primary document, so no change over time is shown here.

Sources and method

  • AI usage figures come from the Royal College of Radiologists 2025 workforce censuses, covering 159 trusts and health boards and 60cancer centres across all four nations. The published share divides by the organisations answering the AI question rather than by the census, so it is reproduced as published rather than recalculated. Figures are redrawn from the RCR's numbers with attribution, and its own charts are not reproduced.
  • No UK register of AI-enabled medical devices exists to draw on. The MHRA's Public Access Registration Database carries no AI flag and no device classification code that could serve as one, and records no authorisation date, so it cannot be filtered into such a list. The FDA publishes one, running to 1,614 devices.
  • Business-wide adoption figures for the UK and Europe, which count firms of every kind rather than clinical services, sit on our AI adoption statistics overview and the UK series. Those measure a different population and are not comparable with anything here.

Published NHS deployments

Deployments with a published, checkable source. Outcomes are graded: measured means observed after deployment and published, modelled means derived from assumptions, stated means published without a basis given. Most of these were reported between 2020 and 2024, and the NHS publishes little new outcome evidence of this kind, which is itself worth noting.

Named NHS AI and clinical decision-support deployments with their published outcomes and sources
DeploymentSystemPublished outcomes
Delirium decision supportSalford RoyalRules-based
  • Identified delirium cases rose 34% (measured)
  • Average length of stay fell 11% (measured)
  • Around £1.7m saved in the first year (modelled)
NHS England, Supporting clinical decisions with health information technology, 2023
Clinical decision support platformRoyal Free LondonRules-based
  • Term-baby neonatal unit admissions fell from 13% to 6% (measured)
NHS England, Supporting clinical decisions with health information technology, 2023
Electronic prescribing and medicines administrationGateshead HealthRules-based
  • £72,500 a year in medication cost savings (stated)
NHS England, Supporting clinical decisions with health information technology, 2023
Electronic transfusion decision supportOxford University HospitalsRules-based
  • £1.2m saved over four years (stated)
NHS England, Supporting clinical decisions with health information technology, 2023
T-MACS heart-attack decision aidManchester, and emergency departments using the ruleLearned model
  • Ruled out myocardial infarction in 46.5% of 132 chest-pain presentations, false-negative rate 0.08% (measured)
NIHR Evidence, Clinical decision support tools collection, 2020
SMASH prescribing safety dashboardSalford and Greater Manchester primary careRules-based
  • Flagged hazardous prescribing in over 5% of patients, and around 10% missing required monitoring (measured)
NIHR Evidence, Clinical decision support tools collection, 2020
AI chest X-ray triage, AI Diagnostic FundSix imaging networks in EnglandLearned model
  • Covers around 2.8 million chest X-rays a year, roughly a third of the England total (stated)
AI Diagnostic Fund deployment coverage, reported by Harrison.ai, 2024

Alert override is the failure mode all of these are judged against: between 49% and 96% of decision-support alerts are ignored or overridden by clinicians, across studies from 2006 to 2025. Range collated in JMIR Research Protocols.

Clinical AI advice

The difference between a deployment that lands in the table above and one that quietly accrues a ninety per cent override rate is rarely the underlying model. It is the clinical framing, the alert rule design, and whether anyone re-tunes sensitivity after go-live. Those are clinical, statistical and regulatory problems at once.

Sesen AI is one named principal with a doctorate in AI and medical informatics from Oxford, peer-reviewed clinical decision-support work in PLOS One and the Journal of the Royal Society Interface, and current research on clinical language models. Engagements run in weeks rather than quarters, and end in artefacts a medical director, a regulator and an IT team can all sign off.

  • Alert-fatigue audit and rule rebuild

    Fixed fee, 3 to 5 weeks

    For a trust whose prescribers are overriding most drug-interaction or deterioration alerts. Ends in before and after override rates, a revised alert rule set graded by clinical evidence, and a sensitivity curve to choose the operating point.

  • Independent vendor validation

    4 to 6 weeks

    For a procurement team weighing a commercial AI or decision-support product. Ends in a report on calibration, discrimination, subgroup fairness and regulatory readiness, validated against a de-identified sample of your own patients rather than the vendor’s.

  • Deployment plan for a named pathway

    6 to 10 weeks

    For sepsis early warning, delirium screening or post-operative deterioration. Ends in a sequenced rollout plan with pre and post metrics, benchmarked against the deployments listed above.

Engagements start with a 30-minute intro call with the clinical lead or digital programme director. A scoped proposal follows within 48 hours if the shape of work is clear, or a short paid scoping exercise if it is not. Get in touch about a specific deployment or vendor assessment.

Stay in the loop

Get notified when new tutorials and deep-dives are published. No spam, unsubscribe anytime.

Frequently Asked Questions